PLUMBING
Water quality or hazardous materials (lead) testing is available from
local testing labs. All underground piping related to
water supply, waste, or sprinkler use are excluded from this
inspection. Leakage or corrosion in underground piping cannot be
detected by a visual inspection. The temperature pressure relief
valve, at the upper portion of the water heater, is a required
safety valve which should be connected to a drain line of proper size
terminating just above floor elevation. If no drain is
located in the floor a catch pan should be installed with a drain
extending to a safe location. The steam caused by a blow-off
can cause scalding. Improper installations should be corrected.
MAIN LINE:
MATERIAL:
Copper.
CONDITION: Water meter is located: Basement, Valve is operational. Main line is
3/4 inch diameter. Water pressure appears adequate. Appears
serviceable.
SUPPLY LINES:
MATERIAL: Copper.
CONDITION: Appears
serviceable.
WASTE LINES:
MATERIAL:
Plastic. Cast
Iron.
CONDITION: Appears
serviceable.
HOSE
FAUCETS:
OPERATION: Sample
operated, appeared serviceable.
WATER HEATER:
TYPE:
Oil.
SIZE:
40 Gallons.
LOCATION: Basement.
CONDITION: Appears
serviceable.
FUEL
SYSTEM:
METER/TANK LOCATION: Two
oil tanks located at crawl space. System appears serviceable.
HEATING - AIR CONDITIONING
HEATING SYSTEM DESCRIPTION:
LOCATION OF PRIMARY UNIT:
Basement.
SYSTEM TYPE: Forced
hot water boiler. Baseboard.
FUEL TYPE AND NOTES:
Oil.
CAPACITY OF UNIT:
230,000 BTU
APPROXIMATE AGE IN YEARS:
22 years.
HEATING SYSTEM CONDITION:
PRIMARY UNIT:
Appears operational.
BURNERS/HEAT EXCHANGE: Burner
Flame(s) appear typical.
PUMP/BLOWER FAN: Appears
Serviceable.
VENTING: Appears
serviceable.
NORMAL CONTROLS: Appear
serviceable.
GENERAL SUGGESTIONS: Suggest
cleaning/servicing blower motor, pilot light, vent system and burners.
AIR CONDITIONING:
TYPE: Wall
Mount units.
POWER SOURCE: 110
Volt.
SYSTEM CONDITION: Most
wall unit are operating well. A/C Unit in rear bedroom is missing a thermostat knob. A/C unit at
Den is missing a rear exterior cover.
ELECTRICAL SYSTEM
Any electrical repairs attempted by anyone other than a licensed
electrician should be approached with caution. The power to
the entire house should be turned off prior to beginning any repair
efforts, no matter how trivial the repair may seen.
Aluminum wiring requires periodic inspection and maintenance by a
licensed electrician. Operation of time clock motors is not
verified. Inoperative light fixtures often lack bulbs or have dead
bulbs installed. Light bulbs are not changed during the
inspection, due to time constraints. Smoke Alarms should be installed
within 15 feet of all bedroom doors, and tested regularly.
SERVICE
TYPE
AND CONDITION: Overhead.
110/220 Volt. Circuit breakers. 200 Amp. service. Appears
serviceable.
ELECTRICAL PANELS:
MAIN PANEL LOCATION AND CONDITION:
Basement.
Appears serviceable.
Inspector
Notes: Circuit
and wire sizing correct so far as visible. Grounding system is
present.
CONDUCTORS:
Copper
ENTRANCE CABLES: Copper.
BRANCH WIRING: Copper.
Appears serviceable.
SWITCHES & OUTLETS:
CONDITION: Reverse
polarity is noted at one of the kitchen outlets.